You are here ALAT LAB LINGKUNGAN

Alat Laboratori - PD. Karya Mitra Usaha

ALAT LAB LINGKUNGAN

E-mail Print PDF

Survey Meter
Survey Meter

"Fungsi : monitor alpha, beta, gamma and x-ray radiation
▪  Monitor alpha, beta, gama and X-ray radiation
▪  Range : 0-300,000 cpm  
▪  4-digit LCD readout 
▪  Red LED count light 
▪  Audible beeper (can be swiched off) 
▪  External calibration controls 
▪  Adjustable timer with : 
1-minutes sampling periods from 1 to 10 minutes 10-minutes sampling periods from 10 to 60 minutes 1-hour sampling periods from 1 to 24 hour
▪  Operates 200 hours on 9 V battery 
▪  Wipe test plate positions wipe directly in front of detector at 1 cm distance. Protects GM from damagel contamination when meter is not in use
▪  Acessories :
 a)  Wipe Test Plate and Adapter (installed) 
 b)  Carrying case 
 c)  Certificate of Orgin (manufacturing) 
 d)  Manual Book"


Fan Anemometer
Fan Anemometer

"Type : FA-320
Fungsi : untuk mengukur kecepatan angin
Range        
•  Air speed   :   0,3 to 35 m/s
•  Air flow   :   0 to 99999 m³/s
•  Temperature   :   -20 to 60 ?C
•  R/H   :   0 to 100% RH
•  Dew point   :   -68 to 70 ?C
•  Wet bulb   :   -22 to 70 ?C
Accuracy        
•  Air speed   :   ±5% v.M
•  Air flow   :   ±5% v.M
•  Temperature   :   ±0.6?C
•  R/H   :   ±3% RH (10 to 90% RH) ; Otherwise 5% RH       
Resolution        
•  Air speed   :   0,1
•  Air flow   :   0,1 ( 0 to 9999,9) ; 1 (10000 to 99999)
•  Temperature   :   0.1?C
•  R/H   :   0.1% RF
•  Dew point   :   0.1?C
•  Wet Bulb   :   0.1?C 
Size        
•  Fan   :   170 x 77 x 40mm
•  Instrument   :   175 x 70 x 33mm 
Supply
•  Batteries   :   4 x AAA (includes)"


Lux Meter KMAR823
Lux Meter KMAR823

"Measuring Range : 1 to 100,000 Lux
Sampling Rate : 1,5 times/sec
Accuracy : < 3%rgd ± 0.5% f.s
Accuracy : ± 4% rgd ± 10 dgts if > 10 000 Lux
Accuracy : Calibrated to standard incadescent lampe at color temperature 2856K)
Power supply : 9 volt battery
Operation Condition : 0ºC to 50ºC < 80% rH condensing
Weight : 178 gr
Product size : 207 x 70 x 29 mm
Included : Lux Meter and sensor, Battery alkaline 1 Pcs, Carrying Case, Instruction manual"


Portable Digital Lux Meter
Portable Digital Lux Meter

"Portable digital lux meter LX-100
For workstations, offices, sport installations, parking, commercial centers… Dedicated to control and monitoring illuminance.
Measuring range : from 0,1 to 150 000 lux (from 0,01 to 13940 fc).
Supplied with calibration certificate.

Technical data:
Display illuminance for local measurements
With timed measurement : min., max. and average values
Pause function to eliminate any unrepresentative illuminance and display for local measurements
Relative measurement to a reference point for the quantification of a luminous contribution or an illuminance decrease.
Sensing element in silicon photodiode (spectral responsivity in accordance with photonic curve CIE)"


Indoor Air Quality Monitor
Indoor Air Quality Monitor

"Indoor Air Quality Monitor AQ-200
ª ) Gas Range Accuracy CO2 : 0 to 5000 ppm ± 3% of reading CO: 0 to 1000 ppm ± 5 ppm Temperature : -20 to 80 º C -20 to + 80 º C Hygrometer : 5 to 95% RH
ª ) Ambient Temperature : -20 to + 80 º C
ª ) Measuring Element
: CO2, NDIR
: CO, Electrochemical Temperature, PT100 Class A Hygrometry, capacitive hygrometry sensor
ª ) Housing : Shock-proof made ABS, IP54 protection
ª ) Keypad : Metal-coated with 5 keys
ª ) Conformity : Electromagnetical compatibility
ª ) Power supply : 4 Alkaline battery 1, 5V
ª ) Operating temperature : from o to 50 º C
ª ) Storage temperature : from -20 to 80 º C
ª ) Auto shut-of : Adjustable from o to 120 min
ª ) Display : 128 x 128 pixels ( graphic display) '
: Dim, 50 x 54 mm
: Blue backlight
: Display of 6 measurements
ª ) Languages : French, English, Dutch, Germany Italian, Spanish, Portuguese, Swedish Norwegian, Finn, Danish"


Indoor Air Quality Monitor
Indoor Air Quality Monitor

"Indoor Air Quality Monitor AQ-100
Type  :  KIRAY-100                          
Product  :  Kimo Instruments (France)                 
Fungsi  :  Untuk mengukur Suhu dengan sinar Infrared        
                                       
▪  Spectral response : 8 - 14 µm              
▪  Optical : D.S : 20:1 (13 mm at 260 mm)  
▪  Temperature rage : -50 to + 800 ºC           
▪  Accuracy : -50 to +20ºC : ±2,5ºC        
                     :  +20 to +300ºC : ±1% of reading ±1ºC
                     :  +300 to +800ºC : ±1,5%      
▪  Display resolution :  0,1ºC                 
▪  Display : 4 digits with LCD backlighted display
▪  High/low alarm :  Flashing signal on display and beep
                                    Signal with ajustable thershold.  
▪  Response time : 150 ms                 
▪  Autonomy : 105 h (inactive laser and backlight)  
                       : 20 h (active laser and backlight)  
▪  Power supply : Alkaline 9V Battery           
▪  Size / Weight : 145x95x40mm / 180 g (include battery)"


Industrial Gas Analyzer
Industrial Gas Analyzer

"E4400 Industrial Gas Analyzer
Up to Four Gas Sensors:
O2, CO, NO, & NO2 OR O2, CO, NO, & SO2

Dilution Pump For CO Auto-Range Measurements Up To 50,000 ppm
Low NOx Capable with 0.1ppm resolution
Gas Sensors are Pre-Calibrated & Field Replaceable
Efficiency, Excess Air, & CO2 Calculations
Built-In Impact Printer (non-thermal)
Stack Gas & Air Temperature Measurements
Draft & Differential Pressure Measurements
External Water Trap for Condensate Removal
Rechargeable Lithium Ion Battery Pack
Unbreakable Metal Hose Connectors
Internal Memory (up to 900 tests)
PC Software Package"


Hand Held Industrial Combustion & Emissions Analyzer
Hand Held Industrial Combustion & Emissions Analyzer

"Type : E-2200
Fungsi : untuk memonitoring emisi pada gas buang (sumber tidak bergerak)
▪  O2 Sensor : 0 to 25 % 
▪  CO Sensor : 0 to 8,000 ppm 
▪  NO/Nox Sensor  :  0 to 4,000 ppm
▪  CO2-Calculation  :  0 to 99.9%
▪  Flue Gas & Air Temperature Measurement
▪  Draft & Differential Pressure Measurement
▪  Efficiency, Losses & Excess Air Calculations
▪  300mm probe, 800ºC max, with 3m dula hose
▪  External water trap with filter cartridge
▪  Rechargeable Batteries & AC Charger
▪  Internal Memory 600 test
▪  Internal Impact Printer (Non-Thermal)
▪  Magnetic Support
▪  PC Software Package
▪  ABS Hard Plastic Carrying Case
▪  Operating Instructions
▪  Calibration Certificate
▪  Filter Cartridge
▪  Printer Paper Roll
▪  Printer Ribbon"


Real-Time Particulate Monitors
Real-Time Particulate Monitors

"Fungsi: untuk monitoring debu TSP, PM10, PM2,5 & PM1.0µM
Display : Large Alphanumeric LCD-4 line, 20 character display
Operation : Four key splash proof membrane switch - menu driven
Calibration : Gravimetric reference NIST traceable - SAE fine test dust
Accuracy : ± 10% to filter gravimetric SAE fine test dust
Sensing range : 0.001-20.0 mg/m³ or .01 - 200.0 mg/m³ (opt)
Particulate size range : 0.01 - 100 µm
Precision : ± .003 mg/m³ (3 µg/m³)
Sampling flow rate : 1.0 - 5.0 liters/minute
Filter cassette : 47mm FRM style; Alarm output : 90db at 3 ft
Recording time : 1 second to 15 months
Sampling rate : 1 sec, 10 sec, 1 min, and 30 min
Data storage : 21, 600 data points
Memory & time storage : >5 years
Real-time clock & display : Hours, Min, Sec, Day, Month, Year
Data display : Concentration range in mg/m³ & TWA, MAX, MIN, STEL, Date, Time; Digital output : RS-232
Temperature : Operation: -10°C to 50°C; Storage: -20°C to 70°C
DustComm Pro Software : Windows driven for graphical and data translation
Power : Rechargeable and interchangeable battery
Operating time : >24 hours on battery
Charging time: Approx 22 hours; Humidity : 95% non-condensing; Dimensions (case) : 14.0"" x 6.0"" x 10.0""
Weight : 12 lbs."


TFIA Series High Volume Air Samplers
TFIA Series High Volume Air Samplers

"Staplex® Model TFIA series High Volume Air Samplers

Indoor or outdoor sampling of airborne particulates
0-70 cubic feet per minute (cfm) [0-2 cubic meters per minute (cmm)] flow range
Spot or continuous monitoring
Portable and lightweight
Built-in rotometer for instantaneous flow reading
Includes 4"" (10.16 cm) diameter filter holder assembly
For use in normal, non-explosive atmospheres"


Impinger CS-596-AC
Impinger CS-596-AC

"- Kapasitas Hisap : Maximum 2,0 Liter udara/menit tanpa beban
- Teknologi Pengisap : Vibrasi katup ganda
- Jumlah Pompa Hisap : 5 unit (independent)
- Pengatur Hisapan : Saklar putar bertahap  (independent)
- Lubang Hisap : 5 buah ukuran 1/4 inch
- Lubang Tiup/Ukur : 5 buah ukuran 1/4 inch
- Catu Daya : AC 220V/50Hz/24VA
- Dimensi Mekanikal : Pjg 51 cm, Lbr 21 cm; Tinggi 22 cm, Berat 5 kg
- Perlengkapan Utama :
     5 unit tabung reaksi (impinger); 5 unit tabung pengaman
     1 lot selang fleksibel (1/4 inch), 1buble flow meter.
- Kemampuan Operasi : 24 Jam (endurance test)."


Sound Level Meter KMAR 814
Sound Level Meter KMAR 814

"Sound Level Meter
Measuring Range : 30~130dB A , ±1,5 dB
Measuring Range : 35~130dB C
Level Range Control Switch : 30dB to 80dB
Level Range Control Switch : 50dB to 100dB
Level Range Control Switch : 60dB to 110dB
Level Range Control Switch : 80dB to 130dB
Frequency Range : 31.5HZ-8.5KHZ
Linearity Range : 50dB
Digit & Resolution : 5Digits & 0.1dB
Bar Graph : 50dB scale at 1dB step monitoring
Time weighting selection : Fast for normal measurement
Time weighting selection: Slow for checking AVERAGE level of fluctuating noise
Frequency Weighting : A weighting for general sound level measurement
Frequency Weighting : C weighting for checking low frequency content of noise
1/2 Inch Electret Condenser Microphone
Sampling Frequency : 2 times/sec
Power Source : 9 Volt alkaline battery
Dimensions : 265(L) × 72(W) × 35(D)mm
Weight : 300g approx."


Anemometer, Humidity meter
Anemometer, Humidity meter

"Anemometer, Humidity meter
Light Meter, Type K Thermometer
Model : LM-8000
* Humidity : 10 to 95 %RH,oC/oF
* Anemometer : 0.4 to 30.0 m/s.
* Anemometer unit : m/s, km/h, MPH, knots, ft/min, oC/oF.
* Light : 0 to 20,000 Lux, 0 to 1,680 Ft-cd, auto range.
* Type K Thermometer : -100 to 1300 oC, oC/oF.
* Data hold, Record (Max., Min.)
* Tiny bone shape with light weight and small size."


LVS ( Low Volume Sampler )
LVS ( Low Volume Sampler )

"Portable, lightweight Low Volume Air Samplers highly effective for accurate samples from immediate vicinity of sampler for air pollutants; asbestos fibers; radioactive particles; industrial, governmental, hospital; mine air hazards; etc. Suitable for mobile or fixed position operation in normal non-explosive atmospheres.
Flow Control :
Fully adjustable flow control valve on direct-reading rotometer, settable over the full flow range. Accurate to ± 5% full scale.

Specifications
Model LV-2
Flow rate 15-35 L/ min.
Dimension / Weight 4 "" x 4 "" x 7 "" / 2.7 kg
Power supply 220-240 Volts AC, 50-60 Hz"


Flue Gas Analyzer
Bacharach
Flue Gas Analyzer Bacharach

"Flue Gas Analyzer + Oppt
Measurement Ranges 
Primary/Ambient Air Temperature : -4° to 999°F
Stack Temperature : -4° to 2192°F
Oxygen : 0 to 20.9%
Carbon Monoxide (H2 Compensated) : 0 to 4,000 ppm
Carbon Monoxide, (High Range) : 4,001 to 20,000 ppm
Nitric Oxide : 0 to 3,000 ppm
Nitrogen Dioxide : 0 to 500 ppm
Sulfur Dioxide : 0 to 5,000 ppm
Pressure/Draft : -72 to +72 inwc
Calculated Ranges:
Combustion Efficiency : 0.1 to 100%
Excess Air : 1.0 to 250%
Carbon Dioxide (Dry Basis)  : 0 to Fuel Dependent Maximum
NOx (NO + NO2) : 0 to 3,500 ppm
NOx referenced to % O2 : 0 to 9,999 ppm
CO referenced to % O2 : 0 to 9,999 ppm
NO referenced to % O2 : 0 to 9,999 ppm
NO2 referenced to % O2 : 0 to 9,999 ppm
SO2 referenced to % O2 : 0 to 9,999 ppm
Accuracy
Oxygen  : ± 0.3% O2 (Flue Gas)
Stack or Flue Gas Temperature : ± 4°F between 32 and 255°F
 (± 2°C between 0 and 124°C); ± 6°F between 256 and 480°F
 (± 3°C between 125 and 249°C); ± 8°F between 481 and 752°F
 (± 4°C between 250 and 400°C)
Primary-air/Ambient Temperature : ± 2°F between 32 and 212°F
 (± 1°C between 0 and 100°C)
Pressure/Draft  : ± 2% Reading or 0.02 inwc -1 to 10 inwc
 ± 3% of Reading between ± -40 and ± 40 inwc
CO  : ± 5% of Reading or ± 10 ppm in the range of 0-2000 ppm CO
 ± 10% of Reading between 2001 to 4,000 ppm
NO  : ± 5% of Reading or ± 5 ppm whichever is greater between 0 to 2000 ppm NO
NO2 : ± 5% of Reading or ± 5 ppm whichever is greater between 0-500 ppm NO2
SO2  : ± 5% of Reading or ± 10 ppm whichever is greater between 0-2000 ppm SO2"


Gas Meter  MSA Gas Meter
Gas Meter MSA Gas Meter

"Description
· Casing engineering plastic
· Measurement drum: Hard vinyl chloride ( R-PVC)
· Pressure loss: 100 Pa
· Operating temperature limit: -10 c to 40 c

Spesifications
WS Type for minute flow, experiment
Pressure loss 100 Pa
Operating pressure limits -1kPa to 10 kPa
Operating temperature limits 4 to 40' C
Measuring range 0.016 - 10 L/ min ( 1 - 600 l/ h)
Drum capacity 1 liter
Weight 2.9 Kg"


Web Officer

Kami siap membantu Anda

Jonny Sinaga :
Harry :
Maglory :
Desna :

 

Karya Mitra Usaha

Ruko Taman Yasmin Sektor VI No. 134,
Jl. Ring Road Utara, Curug Mekar, Bogor

  • Tel: (+62) 251-754 3316
  • Fax: (+62) 251-754 3281
  • Email: karyamitrausaha@yahoo.com